coolind the engine
Instead, the water circulated around the engine is fresh water ( or better still, distilled water) which is then itself cooled using sea water. This fresh water is treated with chemicals to keep it slightly alkaline ( to prevent corrosion) and to prevent scale formation. Of course, if distilled water, which some ships can make from sea water using evaporators, is used then there is a reduced risk of scale formation.
The cooling water pump which may be engine driven or be a separate electrically driven pump pushes the water around the circuit. After passing through the engine, where it removes the heat from the cylinder liners, cylinder heads, exhaust valves and sometimes the turbochargers, it is cooled by seawater and then returns to the engine. The temperature of the cooling water is closely controlled using a three way control valve to by pass the cooler. If the water is allowed to get too cold then it will cause thermal shocking which may lead to component failure and will also allow water and acids to condense on the cylinder bores washing away the lubricating film and causing corrosion. If it gets too hot then it will not remove the heat effectively causing excessive wear and there is a greater danger of scale formation. For this reason the cooling water outlet temperature is usually maintained at about 78°C.
To make up for any leaks in the system there is a header tank, which automatically makes up any deficiency. Vents from the system are also led to this header tank to allow for any expansion in the system and to get rid of any air (if you are familiar with a domestic central heating system then you will see the similarities). The header tank is relatively small, and usually placed high in the engine room. It is deliberately made to be manually replenished, and is fitted with a low level alarm. This is so that any major leak would be noticed immediately. Under normal conditions, the tank is checked once per watch, and if it needs topping up, then the amount logged.
The system will also contain a heater which is to keep the cooling water hot when the engine is stopped, or to allow the temperature to be raised to a suitable level prior to starting. Some ships use a central cooling system, whereby the same cooling water is circulated through the main engine(s) and the alternator engines. This system has the advantage whereby the engines which are stopped are kept warm ready for immediate starting by the engines which are running.
This system shows a typical cooling water circuit for a single medium speed engine with an engine driven main pump and an electrically driven auxiliary circ pump and heater for keeping the engine warm when stopped. | |
On this slow speed engine circuit a drain tank has been included. This is for when the engine is drained down for maintenance purposes. Because of the quantities of water involved and the chemical treatment, it is not economically viable or environmentally responsible to dump the treated water overboard each time. This way the water can be re used. |